Applying negative pressure rapidly or in steps for vacuum extraction assisted vaginal delivery

Assisted vaginal delivery is an important part of obstetric care. Indications for its use include prolonged second stage of labour, actual or potential fetal compromise or distress, and to shorten labour. The established methods facilitate the descent and birth of the infant. A vacuum extractor is becoming the method of choice as it is less likely to injure the mother although failure of attempted vacuum extraction may occur more often than with forceps. Rapid application addresses the benefit of vacuum extraction that can be used when rapid delivery is required. Two good quality randomized controlled trials involving 754 women were identified. Rapid negative pressure application reduced the duration of the procedure without any evidence of differences in outcomes for the mother or infant. Rapid method of negative pressure application should be recommended for vacuum extraction assisted vaginal delivery.

背景

Vacuum extraction is a common technique of assisted vaginal delivery. Traditionally, it has been recommended that the pressure is increased slowly in a stepwise procedure; some have advocated rapid increases in pressure.

目的

To assess the efficacy and safety of rapid versus stepwise negative pressure application for assisted vaginal delivery by vacuum extraction.

搜尋策略

We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (4 April 2012).

選擇標準

Randomized controlled trials and quasi-randomized controlled trials of rapid (within two minutes) versus stepwise (as defined by trialists) increases in negative pressure application for vacuum extraction assisted vaginal delivery.

資料收集與分析

Two review authors independently assessed trials for inclusion and trial quality. The same two review authors extracted data. We entered data into Review Manager software and checked for accuracy. Data extraction and 'Risk of bias' assessment of the contact person's own study were also carried out by three independent assessors who were not involved in the new study.

主要結果

We included two trials involving 754 participants.

One new trial of 660 participants showed the same success rate of vacuum procedure of 98.2% by both methods (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.98 to 1.02).

The two included trials showed significant reductions in the time between applying the vacuum cup and delivery, (one trial (74 women): mean difference (MD) -6.10 minutes, 95% CI -8.83 to -3.37 and the other trial (660 women): with median difference -4.4 minutes, 95% CI -4.8 to -4.0). The two included trials showed no significant difference in detachment rate (RR 0.85, 95% CI 0.38 to 1.86, 2 studies, 754 women), no significant difference in Apgar score below seven at one minute (RR 1.04, 95% CI 0.51 to 2.09) and five minutes (RR 1.00, 95% CI 0.29 to 3.42), no significant differences in scalp abrasions or lacerations, cephalhematoma, subgaleal hemorrhage and hyperbilirubinemia. There were no significant differences between the two methods in all secondary outcomes.

作者結論

The rapid negative pressure application for vacuum assisted vaginal birth reduces duration of the procedure whilst there is no evidence of differences in maternal and neonatal outcomes. Rapid method of negative application should be recommended for vacuum extraction assisted vaginal delivery.

引用文獻
Suwannachat B, Lumbiganon P, Laopaiboon M. Rapid versus stepwise negative pressure application for vacuum extraction assisted vaginal delivery. Cochrane Database of Systematic Reviews 2022, Issue 4. Art. No.: CD006636. DOI: 10.1002/14651858.CD006636.pub3.