跳转到主要内容

Pressurised metered dose inhalers versus all other hand-held inhaler devices to deliver beta-2 agonist bronchodilators for non-acute asthma

This review determined to look at whether fast acting relievers performed better when they were delivered via different inhalers in people with asthma. The authors did not find differences between the devices in lung function measurements that exceeded what would be expected with the play of chance. HFA-metered dose inhalers reduced the requirement for oral steroids. However, the studies reported data in ways that prevented formal statistical combination. More research is required to establish more reliably whether the devices commonly used to deliver reliever medication provide similar efficacy and safety.

研究背景

A number of different inhaler devices are available to deliver beta2-agonist bronchodilators in asthma. These include hydrofluoroalkane (HFA) or chlorofluorocarbon (CFC)-free propelled pressurised metered dose inhalers (pMDIs) and dry powder devices.

研究目的

To determine the clinical effectiveness of pMDI compared with any other available handheld inhaler device for the delivery of short-acting beta-2 agonist bronchodilators in non-acute asthma in children and adults.

检索策略

The Cochrane Collaboration Clinical Trials register was searched for studies as well as separate additional searches carried out on MEDLINE, EMBASE, CINAHL and also on the Current Contents Index as well as the Science Citation Index. In addition, 17 individual online respiratory journals and 12 electronically available clinical trial databases were also searched. The UK pharmaceutical companies who manufacture inhaled asthma medication were contacted in order to obtain details of any published or unpublished studies.

纳入排除标准

The full texts of all potentially relevant articles were reviewed independently by two reviewers.

资料收集与分析

Fixed and random effect models were used. Dichotomous outcomes were assessed using Odds Ratios or Relative Risks (RR) with 95% Confidence Intervals (95% CI).

主要结果

Eighty-four randomised controlled trials were included in this review, but few could be combined to assess a specific outcome for a given delivery device comparison. Only two studies required demonstration of adequate pMDI technique as an entry requirement. There were no difference between a standard CFC containing pMDI and any other device for most outcomes. Regular use of HFA-pMDI containing salbutamol reduced the requirement for short courses of oral corticosteroids (3 trials, 519 patients: RR 0.67; 95% CI 0.49, 0.91); however the total number of exacerbations were unchanged (3 trials, 1271 patients: RR 1.0; 95% CI 0.75, 1.33).

作者结论

In patients with stable asthma, short-acting beta-2 bronchodilators in standard CFC-pMDI's are as effective as any other devices. The effect of HFA-pMDI on requirement for oral corticosteroid courses to treat acute exacerbations should be confirmed. Effectiveness studies that use an intention-to-treat analysis are required.

引用文献
Ram FSF, Brocklebank DDM, White J, Wright JJ, Jones P. Pressurised metered dose inhalers versus all other hand-held inhaler devices to deliver beta-2 agonist bronchodilators for non-acute asthma. Cochrane Database of Systematic Reviews 2002, Issue 2. Art. No.: CD002158. DOI: 10.1002/14651858.CD002158.

我们的Cookie使用

我们使用必要的cookie来使我们的网站工作。我们还希望设置可选的分析cookie,以帮助我们进行改进。除非您启用它们,否则我们不会设置可选的cookie。使用此工具将在您的设备上设置一个cookie来记住您的偏好。您随时可以随时通过单击每个页面页脚中的“Cookies设置”链接来更改您的Cookie首选项。
有关我们使用cookie的更多详细信息,请参阅我们的Cookies页面

接受全部
配置