Pressurised metered dose inhalers versus all other hand-held inhaler devices to deliver beta-2 agonist bronchodilators for non-acute asthma

Također dostupno na

This review determined to look at whether fast acting relievers performed better when they were delivered via different inhalers in people with asthma. The authors did not find differences between the devices in lung function measurements that exceeded what would be expected with the play of chance. HFA-metered dose inhalers reduced the requirement for oral steroids. However, the studies reported data in ways that prevented formal statistical combination. More research is required to establish more reliably whether the devices commonly used to deliver reliever medication provide similar efficacy and safety.

Uvod

A number of different inhaler devices are available to deliver beta2-agonist bronchodilators in asthma. These include hydrofluoroalkane (HFA) or chlorofluorocarbon (CFC)-free propelled pressurised metered dose inhalers (pMDIs) and dry powder devices.

Ciljevi

To determine the clinical effectiveness of pMDI compared with any other available handheld inhaler device for the delivery of short-acting beta-2 agonist bronchodilators in non-acute asthma in children and adults.

Metode pretraživanja

The Cochrane Collaboration Clinical Trials register was searched for studies as well as separate additional searches carried out on MEDLINE, EMBASE, CINAHL and also on the Current Contents Index as well as the Science Citation Index. In addition, 17 individual online respiratory journals and 12 electronically available clinical trial databases were also searched. The UK pharmaceutical companies who manufacture inhaled asthma medication were contacted in order to obtain details of any published or unpublished studies.

Kriteriji odabira

The full texts of all potentially relevant articles were reviewed independently by two reviewers.

Prikupljanje podataka i obrada

Fixed and random effect models were used. Dichotomous outcomes were assessed using Odds Ratios or Relative Risks (RR) with 95% Confidence Intervals (95% CI).

Glavni rezultati

Eighty-four randomised controlled trials were included in this review, but few could be combined to assess a specific outcome for a given delivery device comparison. Only two studies required demonstration of adequate pMDI technique as an entry requirement. There were no difference between a standard CFC containing pMDI and any other device for most outcomes. Regular use of HFA-pMDI containing salbutamol reduced the requirement for short courses of oral corticosteroids (3 trials, 519 patients: RR 0.67; 95% CI 0.49, 0.91); however the total number of exacerbations were unchanged (3 trials, 1271 patients: RR 1.0; 95% CI 0.75, 1.33).

Zaključak autora

In patients with stable asthma, short-acting beta-2 bronchodilators in standard CFC-pMDI's are as effective as any other devices. The effect of HFA-pMDI on requirement for oral corticosteroid courses to treat acute exacerbations should be confirmed. Effectiveness studies that use an intention-to-treat analysis are required.

Citat
Ram FSF, Brocklebank DDM, White J, Wright JJ, Jones P. Pressurised metered dose inhalers versus all other hand-held inhaler devices to deliver beta-2 agonist bronchodilators for non-acute asthma. Cochrane Database of Systematic Reviews 2002, Issue 2. Art. No.: CD002158. DOI: 10.1002/14651858.CD002158.

Naše korištenje kolačića

Koristimo nužne kolačiće kako bi naša web stranica radila. Željeli bismo postaviti i neobavezne analitičke kolačiće koji će nam pomoći da ju poboljšamo. Nećemo postaviti neobavezne kolačiće ako ih ne omogućite. Korištenjem ovog alata postavit će se kolačić na vaš uređaj, kako bi zapamtili vaše postavke. Svoje postavke kolačića možete promijeniti u bilo kojem trenutku klikom na vezu "Postavke kolačića" u podnožju svake stranice.