Effectiveness of Copper-containing intra-uterine devices (coil)

Także dostęne w

Wprowadzenie

Intrauterine devices (IUD) are safe and effective methods of long term reversible contraception. The design, and copper content as well as placement of the copper on IUDs could affect their effectiveness and side-effect profile.

Cele

We compared different copper IUDs for their effectiveness and side effects.

Metody wyszukiwania badań

Multiple electronic databases were searched with appropriate key words and names of the IUDs known to be in the market. We searched the reference lists of papers identified and contacted trialists when possible. There was no language restriction.

Kryteria doboru badań

Randomised controlled trials comparing different IUDs were considered. Trials needed to report on clinical outcomes.

Zbieranie i analiza danych

Data on outcomes and trial characteristics were extracted in duplicate and independently by two reviewers. Meta-analysis results are expressed as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity a random-effects model was applied.

Główne wyniki

We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07% to 2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36% to 6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain, or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomised data on IUD use in nulliparous women.

Wnioski autorów

TCu380A or TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.

Cytowanie
Kulier R, O'Brien P, Helmerhorst FM, Usher-Patel M, d'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database of Systematic Reviews 2007, Issue 4. Art. No.: CD005347. DOI: 10.1002/14651858.CD005347.pub3.

Używamy plików cookie

Używamy niezbędnych plików cookie, aby nasza strona mogła działać. Chcielibyśmy również ustawić opcjonalne pliki cookie do analizy, aby pomóc nam udoskonalić tę stronę. Nie będziemy ustawiać opcjonalnych plików cookie, chyba że je włączysz. Użycie tego narzędzia spowoduje ustawienie pliku cookie na Twoim urządzeniu, aby zapamiętać Twoje preferencje. W każdej chwili możesz zmienić swoje preferencje dotyczące plików cookie, klikając na link "Ustawienia plików cookie" znajdujący się w stopce każdej strony.