跳转到主要内容

Positive end-expiratory pressure for resuscitation of newborn infants at birth

At birth, the lungs of newborn babies are filled with fluid. This fluid must be cleared and replaced with air after birth. While most babies manage by themselves, one in every 20 to 30 newborns receives resuscitation at birth, mostly for absent or ineffective breathing. All babies who are resuscitated receive help to breathe and this is the most important part of neonatal resuscitation. A variety of devices are used to help babies begin their normal breathing. Some of these devices allow the caregivers to give a ‘background pressure’ known as positive end-expiratory pressure, or PEEP, which may help keep the lungs inflated. Currently, there are only two trials which address this issue. Although there were some benefits associated with using PEEP, there is insufficient information to make this a routine part of practice.

研究背景

Effective ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation is initiated with manual ventilation devices which may or not deliver positive end-expiratory pressure (PEEP). PEEP is known to have beneficial effects in preterm animal models and its use is ubiquitous in mechanical ventilation in neonatal intensive care.

研究目的

To determine whether the use of PEEP during positive pressure ventilation at neonatal resuscitation reduces mortality or morbidity.

检索策略

The standard search strategy of the Cochrane Neonatal Review Group was used. Pub Med (1966 to May 2004) was searched using the MeSH headings Infant, Newborn, Resuscitation, Positive Pressure Respiration and the text words Positive End-Expiratory Pressure or PEEP. The Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 1, 2004) was searched using text words Newborn and Resuscitation. No language restrictions were applied. The abstracts of the Society for Pediatric Research and the European Society for Pediatric Research, were searched from 1995-May 2004. Abstracts were also searched in Anaesthesiology, Canadian Journal of Anaesthesia, British Journal of Anaesthesia, Anaesthesia and Intensive Care and Anaesthesia and Analgesia.

纳入排除标准

Randomised and quasi-randomised controlled trials comparing ventilation devices providing PEEP with those not providing PEEP in the resuscitation of infants at birth.

资料收集与分析

Assessment of methodology regarding blinding of randomisation, intervention and outcome measurements as well as completeness of follow-up was planned. We planned to evaluate the treatment effect using a fixed effects model using relative risk (RR), relative risk reduction, risk difference (RD) and number needed to treat (NNT) for categorical data and using mean, standard deviation and weighted mean difference (WMD) for continuous data. We planned an evaluation of heterogeneity to help determine the suitability of pooling results.

主要结果

No studies were found meeting the criteria for inclusion in this review.

作者结论

There is insufficient evidence to determine the efficacy and safety of PEEP during positive pressure ventilation at neonatal resuscitation. Randomised clinical trials comparing positive pressure ventilation with and without PEEP at neonatal resuscitation are warranted.

引用文献
O'Donnell CPF, Davis PG, Morley CJ. Positive end-expiratory pressure for resuscitation of newborn infants at birth. Cochrane Database of Systematic Reviews 2004, Issue 4. Art. No.: CD004341. DOI: 10.1002/14651858.CD004341.pub2.