跳转到主要内容

The use of blunt needles compared to sharp needles for preventing needle stick injuries in surgical staff

Surgeons and their assistants are especially at risk of needle stick injuries during operations. This can lead to infection with HIV or other blood-borne viruses. The use of blunt needles is proposed to prevent needle stick injuries. We reviewed the literature to evaluate the preventive effect of blunt needles compared to sharp needles on needle stick injuries among surgical staff. We searched multiple medical databases (to May 2011). We included studies if they were randomised controlled trials (RCTs) of blunt versus sharp suture needles for preventing needle stick injuries among surgical staff. We located 10 RCTs with 2961 operations in which blunt needles were compared to sharp needles. Six studies focused on abdominal operations, two on vaginal repair and two on hip replacement. On average, a surgeon that used sharp needles sustained one glove perforation per three operations. The use of blunt needles reduced the risk of glove perforations by 54% (95% confidence interval 46% to 62%) compared to sharp needles. The use of blunt needles in six operations will thus prevent one glove perforation. In four studies the use of blunt needles also reduced the number of self-reported needle stick injuries by 69% (95% confidence interval 14% to 68%). Even though surgeons reported that the force needed for the blunt needles was higher, their use of the needles was still rated as acceptable in five out of six studies. We concluded that there is high quality evidence that the use of blunt needles appreciably reduces the risk of contracting infectious diseases for surgeons and their assistants over a range of operations by reducing the number of needle stick injuries. It is unlikely that future research will change this conclusion.

研究背景

Surgeons and their assistants are especially at risk of exposure to blood due to glove perforations and needle stick injuries during operations. The use of blunt needles can reduce this risk because they don't penetrate skin easily but still perform sufficiently in other tissues.

研究目的

To determine the effectiveness of blunt needles compared to sharp needles for preventing percutaneous exposure incidents among surgical staff.

检索策略

We searched MEDLINE and EMBASE (until May 2011), CENTRAL, NHSEED, Science Citation Index Expanded, CINAHL, Nioshtic, CISdoc, PsycINFO, and LILACS (until September 2010).

纳入排除标准

Randomised controlled trials (RCTs) of blunt versus sharp suture needles for preventing needle stick injuries among surgical staff measured as glove perforations or self-reported needle stick injuries.

资料收集与分析

Two authors independently assessed study eligibility and risk of bias in trials and extracted data. We synthesized study results with a fixed-effect model meta-analysis.

主要结果

We located 10 RCTs involving 2961 participating surgeons performing an operation in which the use of blunt needles was compared to the use of sharp needles. Four studies focused on abdominal closure, two on caesarean section, two on vaginal repair and two on hip replacement. On average, a surgeon that used sharp needles sustained one glove perforation in three operations. The use of blunt needles reduced the risk of glove perforations with a relative risk (RR) of 0.46 (95% confidence interval (CI) 0.38 to 0.54) compared to sharp needles. The use of blunt needles will thus prevent one glove perforation in every six operations.

In four studies, the use of blunt needles reduced the number of self-reported needle stick injuries with a RR of 0.31 (95% CI 0.14 to 0.68). Because the force needed for the blunt needles is higher, their use was rated as more difficult but still acceptable in five out of six studies.

The quality of the evidence was rated as high.

作者结论

There is high quality evidence that the use of blunt needles appreciably reduces the risk of exposure to blood and bodily fluids for surgeons and their assistants over a range of operations. It is unlikely that future research will change this conclusion.

引用文献
Saarto A, Verbeek JH, Lavoie M-C, Pahwa M. Blunt versus sharp suture needles for preventing percutaneous exposure incidents in surgical staff. Cochrane Database of Systematic Reviews 2011, Issue 11. Art. No.: CD009170. DOI: 10.1002/14651858.CD009170.pub2.

我们的Cookie使用

我们使用必要的cookie来使我们的网站工作。我们还希望设置可选的分析cookie,以帮助我们进行改进。除非您启用它们,否则我们不会设置可选的cookie。使用此工具将在您的设备上设置一个cookie来记住您的偏好。您随时可以随时通过单击每个页面页脚中的“Cookies设置”链接来更改您的Cookie首选项。
有关我们使用cookie的更多详细信息,请参阅我们的Cookies页面

接受全部
配置