跳转到主要内容

Intravenous in-line filters for preventing morbidity and mortality in neonates

Review question: Does the use of in-line filters on intravenous lines reduce morbidity and mortality in neonates?

Background: Preterm or sick newborn infants are often fed with nutrients and fluids that are delivered directly into a vein. This intravenous delivery can be associated with infection, toxins released by bacteria, and tiny particles that may be in the fluids, such as rubber and plastic, going into the blood. In adults, placing a filter in the intravenous line has been reported to be effective in reducing such risks, and filters are increasingly being recommended for use in newborn infants.

Study characteristics: The review authors searched the medical literature and identified four eligible studies that recruited a total of 704 newborns.

Key findings: Septicaemia and illness, deaths or problems with the intravenous lines were no different with or without a filter.

Conclusions: There is insufficient evidence to recommend the use of intravenous in-line filters to prevent morbidity and mortality in newborn infants.

研究背景

Venous access is an essential part of caring for the sick neonate. However, problems such as contamination of fluids with bacteria, endotoxins and particulates have been associated with intravenous infusion therapy. Intravenous in-line filters claim to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults and are increasingly being recommended for use in neonates.

研究目的

To determine the effect of intravenous in-line filters on morbidity and mortality in neonates.

检索策略

We used the standard search strategy of the Cochrane Neonatal Review Group. We searched the electronic databases MEDLINE (from 1966 to May, 2015), EMBASE (from 1980 to May, 2015), CINAHL (from 1982 to May 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 5). We did not impose any language restrictions. Further searching included cross references, abstracts, conferences, symposia proceedings, expert informants and journal handsearching.

纳入排除标准

We included randomised controlled trials (RCTs) or quasi-RCTs that compared the use of intravenous in-line filters with placebo or nothing in neonates.

资料收集与分析

We followed the procedures of the Cochrane Neonatal Review Group throughout. We checked titles and abstracts identified from the search. We obtained the full text of all studies of possible relevance. We independently assessed the trials for their methodological quality and subsequent inclusion in the review. We contacted authors for further information as needed. Statistical analysis followed the procedures of the Cochrane Neonatal Review Group.

主要结果

There were four eligible studies that recruited a total of 704 neonates. This review of low to very low quality evidence found that the use of in-line filters compared with unfiltered fluids for intravenous infusion had no statistically significant difference in effectiveness on overall mortality (typical RR 0.87, 95% CI 0.52 to 1.47; typical RD -0.01, 95% CI -0.06 to 0.04; two studies, 530 infants), proven and suspect septicaemia (typical RR 0.86, 95% CI 0.59 to 1.27; typical RD -0.02, 95% CI -0.09 to 0.04; two studies, 530 infants), or other secondary outcomes (including local phlebitis and thrombus, necrotising enterocolitis, duration of cannula patency, length of stay in hospital, number of catheters inserted and financial costs).

作者结论

There is insufficient evidence to recommend the use of intravenous in-line filters to prevent morbidity and mortality in neonates.

引用文献
Foster JP, Richards R, Showell MG, Jones LJ. Intravenous in-line filters for preventing morbidity and mortality in neonates. Cochrane Database of Systematic Reviews 2015, Issue 8. Art. No.: CD005248. DOI: 10.1002/14651858.CD005248.pub3.