跳转到主要内容

Absorbable stitches for repair of episiotomy and tears at childbirth

Approximately 70% of women who have a vaginal birth will experience some degree of damage to the perineum, due to a tear or cut (episiotomy), and will need stitches. This damage may result in perineal pain during the two weeks after the birth, and some women experience long-term pain and discomfort during sexual intercourse. The impact of perineal trauma can be distressing for the new mother when she is trying to cope with hormonal changes and the demands of her baby, and it can have a long-term effect on her sexual relationship. Most modern materials that are used to stitch the perineum are gradually absorbed and do not need to be taken out. Sometimes, however, stitches have to be removed by the doctor or midwife. A small number of perineal wounds come open (break down) or have delayed healing, and some of these may need to be re-stitched.

This review includes 18 randomised controlled trials with 10,171 women and looks at catgut and synthetic materials used to stitch the perineum after childbirth. It also includes a more recently produced material which has been specially designed to be absorbed more quickly. The main findings were that women stitched with synthetic materials had less pain in the first three days after delivery and needed fewer drugs to relieve pain in the 10 days after giving birth, compared with women stitched with catgut. There was evidence that synthetic stitches were not always readily absorbed and some women with these stitches needed them to be removed. Women experienced similar short and long-term pain with standard absorbable synthetic materials and more rapidly absorbing stitches. However, in one trial, fewer women with rapidly absorbing stitches reported using pain-relieving drugs during the 10 days after delivery, and there was less need for these stitches to be removed. When catgut and glycerol-impregnated catgut were compared the results were similar, although the latter was associated with more short-term pain. One trial examined monofilament and standard synthetic stitches and there was little difference between the two materials in terms of pain and wound healing. As well as the type of material used, other factors such as the technique used to carry out the stitching (using a continuous thread or a series of separately tied stitches) and the skill of the person carrying out the procedure, may also affect the amount of pain and the way perineal wounds heal.

研究背景

Approximately 70% of women will experience perineal trauma following vaginal delivery and will require stitches. This may result in pain, suture removal and superficial dyspareunia.

研究目的

To assess the effects of different suture materials on short- and long-term morbidity following perineal repair.

检索策略

We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (February 2010).

纳入排除标准

Randomised trials comparing different suture materials for perineal repair after vaginal delivery.

资料收集与分析

Two review authors independently assessed trial quality and extracted data.

主要结果

We included 18 trials with 10,171 women; comparisons included: catgut with standard synthetic (nine trials), rapidly absorbing synthetic (two trials), and glycerol impregnated catgut sutures (two trials); and standard synthetic sutures with rapidly absorbing synthetic (five trials) and monofilament sutures (one trial).

Compared with catgut, standard synthetic sutures were associated with less pain up to three days after delivery (risk ratio (RR) 0.83, 95% confidence interval (CI) 0.76 to 0.90); and less analgesia up to ten days postpartum (RR 0.71, 95% CI 0.59 to 0.87). More women with catgut sutures required resuturing (15/1201) compared with synthetic sutures (3/1201) (RR 0.25, 95% CI 0.08 to 0.74); while more women with standard synthetic sutures required the removal of unabsorbed suture material (RR 1.81, 95% CI 1.46 to 2.24). Comparing standard synthetic with rapidly absorbing sutures, short- and long-term pain were similar; in one trial fewer women with rapidly absorbing sutures reported using analgesics at 10 days (RR 0.57, 95% CI 0.43 to 0.77). More women in the standard synthetic suture group required suture removal compared with those in the rapidly absorbed group (RR 0.24, 95% CI 0.15 to 0.36). There was no evidence of significant differences between groups for long-term pain (three months after delivery) or for dyspareunia at three, or at six to 12 months. When catgut and glycerol impregnated catgut were compared, results were similar for most outcomes, although the latter was associated with more short-term pain. One trial examining monofilament versus standard polyglycolic sutures found no differences for most outcomes.

作者结论

Catgut may increase short-term pain compared with synthetic sutures. There were few differences between standard and rapidly absorbing synthetic sutures but more women needed standard sutures removing. For other materials, there was insufficient evidence to draw conclusions. Findings should be interpreted in the context of the related Cochrane review on suturing techniques.

引用文献
Kettle C, Dowswell T, Ismail KMK. Absorbable suture materials for primary repair of episiotomy and second degree tears. Cochrane Database of Systematic Reviews 2022, Issue 3. Art. No.: CD000006. DOI: 10.1002/14651858.CD000006.pub2.

我们的Cookie使用

我们使用必要的cookie来使我们的网站工作。我们还希望设置可选的分析cookie,以帮助我们进行改进。除非您启用它们,否则我们不会设置可选的cookie。使用此工具将在您的设备上设置一个cookie来记住您的偏好。您随时可以随时通过单击每个页面页脚中的“Cookies设置”链接来更改您的Cookie首选项。
有关我们使用cookie的更多详细信息,请参阅我们的Cookies页面

接受全部
配置