Supportive devices for preventing and treating subluxation of the shoulder after stroke

There is insufficient evidence to conclude that supportive devices are effective in the prevention and treatment of subluxation of the shoulder after stroke. Shoulder subluxation is one of the most common secondary musculoskeletal problems after stroke which can cause pain and hinder the recovery of upper limb function. Supportive devices have traditionally been applied to treat shoulder subluxation. This review of four trials found insufficient evidence to conclude whether supportive devices prevent subluxation or not and found no evidence to conclude whether supportive devices can reposition the head of humerus in the glenoid fossa of an already subluxed shoulder.

Wprowadzenie

Supportive devices such as slings, wheelchair attachments and orthoses have been used to treat subluxation of the shoulder after stroke.

Cele

To investigate the effect of supportive devices in preventing subluxation, re-positioning the head of humerus in the glenoid fossa, decreasing pain, increasing function and adversely increasing contracture in the shoulder after stroke.

Metody wyszukiwania badań

We searched the Cochrane Stroke Group Trials Register (last searched on 22 March 2004). In addition, we searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 1, 2004), MEDLINE (1966 to March 2004), CINAHL (1982 to March 2004), EMBASE (1974 to March 2004), AMED (1985 to March 2004) and the Physiotherapy Evidence Database (PEDro, March 2004). We also handsearched conference proceedings and contacted authors for additional information.

Kryteria doboru badań

Studies were included if they were: randomised, quasi-randomised or controlled trials; participants had a stroke; intervention was supportive devices; and subluxation, pain, function or contracture were measured.

Zbieranie i analiza danych

Two independent reviewers examined the identified studies which were assessed for methodological quality and analysed as (1) supportive devices versus no supportive devices or (2) two supportive devices.

Główne wyniki

Four trials (one on slings, three on strapping - 142 participants) met the inclusion criteria. One trial testing a hemisling versus no device reported that no participants had subluxation greater than 10 mm, the same number had lost more than 30 degrees of shoulder external rotation (Peto odds ratio (OR) 1.00, 95% confidence interval (CI) 0.1 to 9.3), and more participants in the hemisling group had pain (Peto OR 8.7, 95% CI 1.1 to 67.1). The other three showed that strapping was effective in delaying the onset of pain (weighted mean difference (WMD) 14 days, 95% CI 9.7 to 17.8), but was ineffective in reducing pain severity (WMD -0.7 cm on a visual analogue scale, 95% CI -2.0 to 0.7), increasing upper limb function (WMD 0.8, 95% CI -1.5 to 3.1) or affecting the degree of contracture (WMD -1.4 degrees, 95% CI -10.9 to 8.1) at the shoulder.

Wnioski autorów

There is insufficient evidence to conclude whether slings and wheelchair attachments prevent subluxation, decrease pain, increase function or adversely increase contracture in the shoulder after stroke. There is some evidence that strapping the shoulder delays the onset of pain but does not decrease it, nor does it increase function or adversely increase contracture.

Cytowanie
Ada L, Foongchomcheay A, Canning CG. Supportive devices for preventing and treating subluxation of the shoulder after stroke. Cochrane Database of Systematic Reviews 2005, Issue 1. Art. No.: CD003863. DOI: 10.1002/14651858.CD003863.pub2.

Używamy plików cookie

Używamy niezbędnych plików cookie, aby nasza strona mogła działać. Chcielibyśmy również ustawić opcjonalne pliki cookie do analizy, aby pomóc nam udoskonalić tę stronę. Nie będziemy ustawiać opcjonalnych plików cookie, chyba że je włączysz. Użycie tego narzędzia spowoduje ustawienie pliku cookie na Twoim urządzeniu, aby zapamiętać Twoje preferencje. W każdej chwili możesz zmienić swoje preferencje dotyczące plików cookie, klikając na link "Ustawienia plików cookie" znajdujący się w stopce każdej strony.