移至主內容

Not enough evidence to show the effect of synthetic membranes when compared with cellulose membranes for haemodialysis

亦提供以下語言

When the kidney fails the blood cannot be filtered properly. Protein breakdown and water need to be removed by haemodialysis, a mechanical process that passes blood over a special filtering membrane. Natural membranes such as cellulose are used. The more expensive synthetic types are considered more compatible as they cause less of an immune response but it is not clear how real clinical outcomes are affected. The review compared synthetic membranes with cellulose/modified cellulose membranes. Not enough evidence was found to show a beneficial effect for synthetic membranes although some improvements were noted. More research is needed.

背景

When the kidney fails the blood-borne metabolites of protein breakdown and water cannot be excreted. The principle of haemodialysis is that such substances can be removed when blood is passed over a semipermeable membrane. Natural membrane materials include cellulose or modified cellulose, more recently various synthetic membranes have been developed. Synthetic membranes are regarded as being more "biocompatible" in that they incite less of an immune response than cellulose-based membranes.

目的

To assess the effects of different haemodialysis membrane material in patients with end-stage renal disease (ESRD).

搜尋策略

We searched MEDLINE, EMBASE, PreMEDLINE, HealthStar CINAHL, the Cochrane Central Register of Controlled Trials (CENTRAL), Biosis, SIGLE, CRIB, UK National Research Register and reference lists of relevant articles. We contacted biomedical companies, known investigators and handsearched selected journals and conference proceedings.
Date of most recent search: June 2004.

選擇標準

All randomised controlled trials (RCTs) or quasi-RCTs comparing different haemodialysis membrane material in patients with ESRD.

資料收集與分析

Two reviewers independently assessed the methodological quality of studies. Data was abstracted onto a standard form by one reviewer and checked by another. Risk ratio (RR) and mean difference (MD) with 95% confidence intervals (CI))

主要結果

Thirty two studies were identified. Pre-dialysis ß2 microglobulin concentrations were not significantly lower in patients treated with synthetic membranes (MD -14.67, 95% CI -33.10 to 4.05). When analysed for change in ß2 microglobulin, a fall was only noted with high-flux membranes. The incidence of amyloid was less in patients who were dialysed for six years with high-flux synthetic membranes (one study, RR 0.03, 95% CI 0.00 to 0.54). There was a significant difference in favour of the synthetic (high-flux) membrane in comparison to cellulose membranes for triglycerides (MD -0.66; 95% CI -1.18 to -0.14) but not for modified cellulose membranes. Dialysis adequacy measured by Kt/V was marginally higher when cellulose membranes were used (MD -0.10; 95% CI -0.16 to 0.04), whereas synthetic membranes achieved significantly higher Kt/V values when compared with modified cellulose membranes (MD 0.20, 95% 0.11 to 0.29) . There were no data on quality of life measures.

作者結論

We found no evidence of benefit when synthetic membranes were compared with cellulose/modified cellulose membranes in terms of reduced mortality no reduction in dialysis-related adverse symptoms. Despite the relatively large number of RCTs undertaken in this area none of the included studies reported any measures of quality of life.

引用文獻
MacLeod AM, Campbell MK, Cody JD, Daly C, Grant A, Khan I, Rabindranath KS, Vale L, Wallace SA. Cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. Cochrane Database of Systematic Reviews 2005, Issue 3. Art. No.: CD003234. DOI: 10.1002/14651858.CD003234.pub2.