Sometimes newborn babies have trouble breathing and need mechanical help. Air can be supplied through a tube inserted into their nose, mouth or trachea (windpipe). There are some potential problems with the tube. Soft tissue can be damaged increasing secretion of fluids that can block the tube, raise blood pressure or cause damage and infections. Using suction to clear the tubes can be done either with or without disconnection from the ventilator. The review of trials found there was some evidence that suctioning without disconnection improves stability. These improvements were small so this can not be recommended as the only way to suction the babies. More research is needed.

Wprowadzenie

Assisted mechanical ventilation is a necessity in the neonatal population for a variety of respiratory and surgical conditions. However, there are a number of potential hazards associated with this life saving intervention. New suctioning techniques have been introduced into clinical practice which aim to prevent or reduce these untoward effects.

Cele

To assess the effects of endotracheal suctioning without disconnection in intubated ventilated neonates.

Metody wyszukiwania badań

The review has drawn on the search strategy for the Cochrane Neonatal Review Group. A comprehensive search of Cochrane databases, MEDLINE and CINAHL, and the Society for Pediatric Research abstracts was undertaken by the review authors (July 2011).

Kryteria doboru badań

All trials that utilised random or quasi-random patient allocation and in which suctioning with or without disconnection from the ventilator was compared.

Zbieranie i analiza danych

Standard methods of the Cochrane Neonatal Group were used. Each review author separately reviewed trials for eligibility and quality and extracted data; they then compared and resolved differences. Analysis was performed using the fixed-effect model and outcomes were reported using relative risk (RR) for categorical data and mean difference (MD) for outcomes measured on a continuous scale.

Główne wyniki

Four trials (252 infants) were included in this review. The trials employed a cross-over design in which suctioning with or without disconnection was compared. Suctioning without disconnection resulted in a reduction in episodes of hypoxia (typical RR 0.48, CI 95% 0.31 to 0.74; 3 studies; 241 participants). There were also fewer infants who experienced episodes where the transcutaneous partial pressure of oxygen (TcPO2) decreased by > 10% (typical RR 0.39, 95% CI 0.19 to 0.82; 1 study; 11 participants). Suctioning without disconnection resulted in a smaller percentage change in heart rate (weighted mean difference (WMD) 6.77, 95% CI 4.01 to 9.52; 4 studies; 239 participants) and a reduction in the number of infants experiencing a decrease in heart rate by > 10% (typical RR 0.61, CI 0.40 to 0.93; 3 studies; 52 participants).The number of infants having bradycardic episodes was also reduced during closed suctioning (typical RR 0.38, CI 95% 0.15 to 0.92; 3 studies; 241 participants).

Wnioski autorów

There is some evidence to suggest suctioning without disconnection from the ventilator improves the short term outcomes; however the evidence is not strong enough to recommend this practice as the only method of endotracheal suctioning. Future research utilising larger trials needs to address the implications of the different techniques on ventilator associated pneumonia, pulmonary morbidities and neurodevelopment. Infants less than 28 weeks also need to be included in the trials.

Cytowanie
Taylor JE, Hawley G, Flenady V, Woodgate PG. Tracheal suctioning without disconnection in intubated ventilated neonates. Cochrane Database of Systematic Reviews 2011, Issue 12. Art. No.: CD003065. DOI: 10.1002/14651858.CD003065.pub2.

Używamy plików cookie

Używamy niezbędnych plików cookie, aby nasza strona mogła działać. Chcielibyśmy również ustawić opcjonalne pliki cookie do analizy, aby pomóc nam udoskonalić tę stronę. Nie będziemy ustawiać opcjonalnych plików cookie, chyba że je włączysz. Użycie tego narzędzia spowoduje ustawienie pliku cookie na Twoim urządzeniu, aby zapamiętać Twoje preferencje. W każdej chwili możesz zmienić swoje preferencje dotyczące plików cookie, klikając na link "Ustawienia plików cookie" znajdujący się w stopce każdej strony.
Bardziej szczegółowe informacje na temat używanych przez nas plików cookie można znaleźć na naszej stronieStrona plików cookies

Zaakceptuj wszystkie
Skonfiguruj