Skoči na glavni sadržaj

Beclomethasone at different doses for chronic asthma

Inhaled steroids help control inflammation in the airways of the lung. There are numerous different preparations available, and we have assessed how varying the dose of beclomethasone (BDP) affects asthma in this review. There was a limited amount of evidence that 800mcg/d was superior to 400mcg/d in improving morning and evening peak flow. More research into the effects of different doses of BDP is required.

Uvod

Beclomethasone dipropionate (BDP) is available in a wide range of daily doses for the treatment of long-term asthma.

Ciljevi

To assess the evidence for a dose response relationship for BDP in the treatment of long-term asthma.

Metode pretraživanja

We searched the Cochrane Airways Group trial register, Cochrane Controlled Trials Register (The Cochrane Library issue 1 1999) and references lists of articles. Authors and Glaxo Wellcome UK were contacted to identify eligible studies. We also hand searched the proceeding from relevant respiratory society meetings, the British Journal of Clinical Research and the European Journal of Clinical Research for studies.

Kriteriji odabira

Prospective, randomised trials comparing two or more daily doses of BDP in patients over the age of two years with long-term asthma.

Prikupljanje podataka i obrada

Trials were selected for inclusion and scored for quality by two reviewers. Data were extracted by one reviewer. Authors were contacted to clarify details of study design and retrieve missing data.

Glavni rezultati

15 trials were included. Methodological quality was variable. Studies rarely gave a clear indication of the degree of asthma control at baseline. Less than two-fold to five-fold dose differences were assessed by different studies. The results are reported as weighted mean differences (WMD) with 95% confidence limits (95% CI). The number of trials (N) contributing to each outcome is stated. In non-oral steroid treated asthmatics a small advantage of BDP 800 mcg/d over 400 mcg/d was apparent for improvement in morning peak expiratory flow rate (PEFR) compared to baseline, WMD 11 L/min (95% CI 4 to 19 L/min) N=2; improvement in forced expired volume in one second (FEV1) compared to baseline, WMD 9 ml (95% CI 3 to 140) N=1; and reduction in night-time symptom score compared to baseline, WMD 0.13 (95% CI 0.04 to 0.22) N=1. Studies that assessed BDP 1000 v 500 mcg/d and BDP 1600 v 400 mcg/d demonstrated significant advantage of higher dose over lower dose for histamine bronchial hyper-responsiveness (BHR) and percentage improvement in FEV1 compared to baseline. No differences between higher and lower daily doses of BDP were apparent for daytime symptoms, withdrawals due to asthma exacerbation, oropharyngeal side effects or measures of hypothalamo-pituitary-adrenal (HPA) function. No difference in prednisolone sparing effect was apparent when comparing high dose and low dose BDP in oral corticosteroid (OCS) dependent patients.

Zaključak autora

BDP appears to demonstrate a shallow dose response effect in long-term asthma for a small number of efficacy outcomes over range of daily doses from 400 mcg/d to 1600 mcg/d, although the clinical significance of the improvements afforded by higher doses is questionable.

Citat
Adams NP, Bestall JC, Jones P. Beclomethasone at different doses for chronic asthma. Cochrane Database of Systematic Reviews 2001, Issue 1. Art. No.: CD002879. DOI: 10.1002/14651858.CD002879.

Naše korištenje kolačića

Koristimo nužne kolačiće kako bi naša web stranica radila. Željeli bismo postaviti i neobavezne analitičke kolačiće koji će nam pomoći da ju poboljšamo. Nećemo postaviti neobavezne kolačiće ako ih ne omogućite. Korištenjem ovog alata postavit će se kolačić na vaš uređaj, kako bi zapamtili vaše postavke. Svoje postavke kolačića možete promijeniti u bilo kojem trenutku klikom na vezu "Postavke kolačića" u podnožju svake stranice.